Motor Lead Out Cable JG

Silicone rubber insulated motor wiring-JG

Specification

JYJ-750.jpg

Single Conductor Extruded Insulation.

PRODUCT DESCRIPTION

●Rated temperature:-60℃~+180℃

●Rated voltage:500V/1000V

●Referencestandard:JB6213.4-92

●Solid or stranded ,tinned or bare copper conductor0.5-120mm2

●Insulation:silicon rubber

●Uniform insulation thickness to ensure easy stripping and cutting

●For used leads wiring of F,H insulation class motor

导体

Conductor

绝缘

Insulation

最大导体电阻
Max.Cond.
Resistance

(Ω/Km,20℃)  

25℃时空气敷
设载流量25℃
Cairlaying
Carrying
Current(A)

标准长度
Standard
Put-up
(M/Coil)

规格
AWG

根数/线径
(No/mm)

外径
Dia.
(mm)

厚度
Thickness
(mm)

标称外径
O.D.
(mm)

0.5

16/0.2

0.95



40.1

15

200

0.75

24/0.2

1.25

1.2

3.4±0.1

26.7

17

1.0

32/0.2

1.35

1.2

3.6±0.1

20.0

19

1.5

30/0.25

1.65

1.2

3.8±0.1

13.7

24

100

2.5

49/0.25

2.1

1.2

4.5±0.1

8.21

33

4.0

56/0.3

2.7

1.4

5.1±0.1

5.09

45

6.0

84/0.3

3.3

1.4

6.4±0.2

3.39

58

10

84/0.4

4.7

1.6

7.8±0.2

1.95

80

16

126/0.4

5.8

1.6

8.9±0.2

1.24

107

25

196/0.4

7.4

1.8

10.7±0.2

0.795

138

35

276/0.4

8.6

2.0

12.5±0.3

0.565

171

50

396/0.4

10.4

2.2

14.7±0.3

0.393

210

70

360/0.5

12.5

2.2

16.8±0.5

0.277

269

50

95

475/0.5

15.3

2.4

19.5±0.5

0.21

328

100

509/0.5

16.5

2.4

20.0±0.5

0.196

358

120

608/0.5

17.0

2.4

21.0±0.5

0.164

420