- Agriculture / Food
- Apparel / Textiles / Accessories
- Auto / Transportation
- Bags / Shoes / Accessories
- Electronics
- Electrical Equipment / Components / Telecoms
- Gifts / Sports / Toys
- Health / Beauty
- Home / Lights / Construction
- Machinery / Industrial Parts / Tools
- Metallurgy / Chemicals / Rubber / Plastics
- Packaging / Advertising / Office
cables
-
National standard industrial installation cable AV, AV-90, BV, BV-90 WDZ(N)-BYJ
Scope of application:
Mainly used in the internal connection of electrical equipment.
Product standards: GB/T 5023.3, IEC 60227-3, JB/T 8734.2, JB/T 8734.4
Cable structure and technical characteristics:
1) Single or multiple copper conductors, in accordance with GB/T 3956 and IEC 60228 Type 1 or 2 copper conductors or JB/T
Provisions of 8734.4
2)PVC insulation layer
Rated voltage: 300/300V, 300/500V or 450/750V
Temperature range: -15℃ to +70℃ or -15℃ to +90℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 GB/T19666-2019 -
AVR, AVR-90, RV, RV-90 WDZ(N)-RYJ cable
Application: Mainly used in the internal connection of electrical equipment.
Product standards: GB/T 5023.3, IEC 60227-3, JB/T 8734.4
Cable structure and technical characteristics:
1) Single or multiple copper conductors, in accordance with GB/T 3956 and IEC 60228 Type 5 copper conductors or JB/T
Provisions of 8734.4
2)PVC insulation layer
Rated voltage: 300/300V, 300/500V or 450/750V
Temperature range: -15℃ to +70℃ or -15℃ to +90℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 GB/T19666-2019 -
AVRS, RVS WDZ-RYJS cable
Application: Mainly used in the internal connection of electrical equipment.
Product standard: JB/T 8734.4 or JB/T 8734.3
Cable structure and technical characteristics:
1) Multi-strand copper conductor, as specified in JB/T 8734.4 or JB/T 8734.3
2)PVC insulation layer
Rated voltage: 300/300V
Temperature range: -15℃ to +70℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 -
AVRS, RVS WDZ-RYJS cable
Application: Mainly used in the internal connection of electrical equipment.
Product standard: JB/T 8734.4 or JB/T 8734.3
Cable structure and technical characteristics:
1) Multi-strand copper conductor, as specified in JB/T 8734.4 or JB/T 8734.3
2)PVC insulation layer
Rated voltage: 300/300V
Temperature range: -15℃ to +70℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 GB/T19666-2019 -
AVVR cable
Application: Mainly used in the internal or external connection of small or micro household appliances or other electrical equipment.
Product standard: JB/T 8734.4
Cable structure and technical characteristics:
1) Multi-strand copper conductor, in accordance with JB/T 8734.4
2)PVC insulation layer
3)PVC sheath layer
Rated voltage: 300/300V
Temperature range: -15℃ to +70℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 -
AVP, AVP-90, RVP, RVP-90 cables
Application: Mainly used in dry environment. Used in industrial plants, mechanical workflow control and inspection systems
Signal and pulse cable. Copper wire braids shield from outside interference such as electromagnetic fields and stray frequencies.
Product standard: JB/T 8734.5
Cable structure and technical characteristics:
1) Single or multiple copper conductors, in accordance with the provisions of JB/T 8734.5
2)PVC insulation layer
3) Copper mesh braid layer
Rated voltage: 300/300V
Temperature range: -15℃ to +70℃ or -15℃ to +90℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 -
RVVP cable
Scope of application:
Mainly used in dry environment. Used as signal and pulse cables in industrial plants, mechanical workflow control and inspection systems.
Copper wire braids shield from outside interference such as electromagnetic fields and stray frequencies.
Product standard:
JB/T 8734.5
Cable structure and technical characteristics:
Single or multiple copper conductors, as specified in JB/T 8734.5
PVC insulation
Copper mesh braided layer
PVC sheath layer
Rated voltage: 300/300V
Temperature range: -15℃ to +70℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2 -
RVVY cable
Scope of application:
Mainly used in dry, wet environment. Used as signals and pulses in industrial plants, mechanical workflow control and inspection systems
Flush the cable.
Product standard:
GB/T 5023.7, IEC 60227-7
Cable structure and technical characteristics:
Multi-strand copper conductor, according to GB/T 3956 and IEC 60228 Type 5 copper conductor
PVC insulation
Yellow-green ground wire (three cores and more)
Copper mesh braided layer
Oil resistant PVC sheath layer
Rated voltage: 300/500V
Temperature range: -15℃ to +70℃
Flame retardant: GB/T 18380.12, IEC 60332-1-2
Oil resistance: GB/T 2951.21, IEC 60811-2-1 -
UL American standard industrial cable UL1007 electronic wire
Scope of application:
Mainly used in the internal connection of electrical equipment.
Product standard:
UL758, UL2556, UL1581
Cable structure and technical characteristics:
Single or multiple strand copper conductors, compliant with UL and ASTM
PVC insulation
Rated voltage: 300V
Temperature range: -20℃ to +80℃
Flame retardant: VW-1, FT1 -
UL2464 electronic wire
Application: Mainly used in the internal connection of electrical equipment.
Product standard: UL758, UL2556, UL1581
Cable structure and technical characteristics:
1) Single or multi-strand copper conductor, in accordance with UL and ASTM regulations
2)PVC insulation layer
3) Braided shield (optional)
4)PVC sheath layer
Rated voltage: 300V
Temperature range: -20℃ to +80℃
Flame retardant: VW-1, FT1