PHO7-Y/D-B 1 hydraulic electric extracorporeal shock wave lithotriptor (B-ultrasound localization)
Main performance and technical instructions
High performance and high-quality discharge telegraphy
Electrode discharge frequency: ≥ 2000 times
Treatment distance 2135cm
Power supply voltage: AC220V (1+1%) 50Hz+1Hz
Working voltage: 3.5KV~6KV, automatically adjustable
Suburban area: radial s7mm, axial s12.5mm
Trigger method: manual, automatic
Technical Parameter
1. Equipment use: To treat urinary tract stones.
2. Shock wave generator:
★ (1) Shock wave source: Large aperture reflection cavity with a diameter of 200mm, excellent focusing performance, and long treatment distance.
(2) It has the function of exchanging hydraulic, electrical, and electromagnetic dual wave sources.
★ (3) High voltage discharge range: 3.5-6KV.
(4) High performance discharge electrode, high-quality brass inner core, discharge frequency ≥ 2000 times.
(5) Peak compressive sound pressure at the focal point: 20Mpa~100Mpa.
(6) Peak expansion sound pressure: 0Mpa~8Mpa.
(7) Shock wave pressure pulse width ≤ 1 μ S.
(8) Shock wave pressure pulse rise time ≤ 0.5 μ S.
★ (9) Focusing body size: radial ± 7mm, axial ± 20mm.
★ (10) The distance between the focus of the pressure pulse and the plane of the pulse generator port is ≥ 135mm.
(11) The shock wave triggering method has manual and automatic modes
3. Shock wave therapy head:
★ (1) The treatment head is suspended above the treatment bed, capable of lifting up and down by 160mm, extending back and forth by 150mm, and rotating laterally by 90 degrees.
★ (2) The hanging treatment head can be extended to rotate from multiple angles, front, back, left, and right, making positioning very easy and flexible.
4. Operating system:
(1) The operation box is hung by the bedside and movable, making it easy for doctors to communicate with patients during operation.
(2) The energy of crushed stones can be adjusted steplessly.
(3) The frequency of gravel discharge can be adjusted.
(4) Equipped with heating control device and overtemperature protection device.
★ 5. Positioning system: A 360 degree B-ultrasound positioning device, where the B-ultrasound probe can move around the focal point from multiple angles.
6. Treatment bed:
(1) The displacement distance of the treatment bed: longitudinal ≥ 110mm, transverse ≥ 130mm.
(2) The minimum displacement is ≤ 1mm in all directions of movement.
(3) The load capacity of the treatment bed is ≥ 135kg.
7. Has passed electromagnetic compatibility testing and meets the requirements. (Provide a copy of the testing report) -
PHO7-Y/D-B1 electromagnetic extracorporeal shock wave lithotriptor (B-ultrasound localization)
Technical instructions
Power supply voltage: AC220V (1+1%) 50Hz+1Hz
Working voltage: 7.5KV-11KV
Focus area range: radial s10mm, axial ≤ 30mm
The distance from the outlet plane of the shock wave generator to the focal point z145cm
The working life of the electromagnetic disc is 21 million times
Treatment method: manual, automatic
Suspended treatment head: The freely moving treatment head can be flexibly adjusted according to the patient's stone location to avoid
The organs and bones in the human body are safe, painless (slightly painful), and lithotripsy is more effective.
Technical Parameter
1. Equipment use: To treat urinary tract stones.
2. Shock wave generator:
★ (1) Shock wave source: Lensless free diaphragm self focusing electromagnetic shock wave generator.
(2) It has the function of exchanging hydraulic, electrical, and electromagnetic dual wave sources.
★ (3) High voltage discharge range: 7.5-11KV.
(4) The service life of the shock wave generator is ≥ 1 million times (if it is not used for more than 1 million times, it will be replaced by the supplier for free), with a counter.
(5) Peak compressive sound pressure at the focal point: 20Mpa~100Mpa.
(6) Peak expansion sound pressure: 0Mpa~8Mpa.
(7) Shock wave pressure pulse width ≤ 1 μ S.
(8) Shock wave pressure pulse rise time ≤ 0.5 μ S.
★ (9) Focusing body size: radial ± 10mm, axial 65mm near the wave source direction, and 120mm away from the wave source direction.
★ (10) The distance between the focus of the pressure pulse and the plane of the pulse generator port is ≥ 145mm.
(11) The shock wave triggering method has manual and automatic modes
3. Shock wave therapy head:
★ (1) The treatment head is suspended above the treatment bed, capable of lifting up and down by 160mm, extending back and forth by 150mm, and rotating laterally by 90 degrees.
★ (2) There is a circular handle in front of the treatment head, which is convenient for doctors to operate and reduces labor intensity.
(3) The hanging treatment head can rotate from multiple angles by extending the hanging axis, making positioning very easy and flexible.
4. Operating system:
(1) The operation box is hung by the bedside and movable, making it easy for doctors to communicate with patients during operation.
(2) The energy of crushed stones can be adjusted steplessly.
(3) The frequency of gravel discharge can be adjusted.
(4) Equipped with heating control device and overtemperature protection device.
★ 5. Water circulation device: The cooling deaerated water circulation device automatically turns on the deaerated water circulation device during treatment to prevent overheating damage to the shock wave generator and extend its service life.
6. Positioning system: A 360 degree B-ultrasound positioning device, where the B-ultrasound probe can move around the focal point from multiple angles.
7. Treatment bed:
(1) The displacement distance of the treatment bed: longitudinal ≥ 110mm, transverse ≥ 130mm.
(2) The minimum displacement is ≤ 1mm in all directions of movement.
(3) The load capacity of the treatment bed is ≥ 135kg.
★ 8. It has passed electromagnetic compatibility testing and meets the requirements. (Provide a copy of the testing report) -
S501 0-A Extracorporeal shock wave lithotriptor (X-ray localization)
Main performance characteristics
1. Dual localization: Using X-ray cross localization
2. B-Super can be added as an auxiliary positioning device
3. The therapeutic body can move in three dimensions and six directions
4. The computer function of the crusher is powerful, and the operation is convenient, accurate, and stable
5. The image data can be frozen and stored with the image dongjie function. Easy to check
Reading, research, and teaching, providing support for hospital networking
6. X-ray generator system: high-frequency or power frequency optional
7. The continuous energy of crushed stones can be described as
Technical parameters of crusher
X-ray system
Voltage regulation range: 50KV-100KV
Current regulation range: 0.5mA -5mA
Shock wave system:
a) Shock wave voltage regulation range: 9KV-14KV
b) Shock wave triggering control method single time. Continuous shock wave generation
The working water for the generator is filtered self prepared water.
The triggering method of shock waves
a) Manual triggering
b) Automatic transmission
The material of the water bag should be medical latex.
Peak sound pressure: The compression peak is 20~50MPa
Peak expansion pressure ≤ 5MPa,
Pressure pulse width pulse width s1 μ
Pressure pulse rise time front ≤ 0.5 μ
Focusing body size and direction S t7mm
Axial direction: S+12.5mm,
The distance between the focal point and the generator end face is 2110mm,
The deviation between focus and target is 3mm
The minimum displacement of the positioning device should not exceed 1mm
The crusher should have a water system control device with water inlet. row
Water and Qigong energy.
X-ray machine C-arm swing angle: 0 "-30
X machine tool surface movement range: X direction (longitudinal)
Exercise: 2z100mm
Direction lateral movement: 100mm,
Work direction (lifting) movement: The bed surface lifting stroke is 2 160mm, and the bed
The distance from the focus of the crushed stone to the bed surface at the lowest position is 2
115mm